|
Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| After-sales Service: | Yes |
| Warranty: | Yes |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency


Smart Monitoring System
Technical specifications
|
X3-PRO G2
|
||||||||
|
Model
|
X3-PR0-8/10/12/15/17/20/25/30K-G2
|
|||||||
|
DC INPUT
|
||||||||
|
Max. PV array input power [Wp]
|
12000
|
15000
|
18000
|
22500
|
25500
|
30000
|
37500
|
45000
|
|
Max. PV input voltage [V]
|
1100
|
|||||||
|
Start startup voltage [V]
|
200
|
|||||||
|
Nominal input voltage [V]
|
650
|
|||||||
|
MPP tracker voltage range [V]
|
160~980
|
|||||||
|
No. of MPP trackers
|
2
|
|||||||
|
Strings per MPP tracker
|
2
|
|||||||
|
Max. input current per MPPT [A]
|
32/32
|
32/32/32
|
||||||
|
Max. short circuit current per MPPT [A]
|
40/40
|
40/40/40
|
||||||
|
AC OUTPUT
|
||||||||
|
Nominal AC output power [W]
|
8000
|
10000
|
12000
|
15000
|
17000
|
20000
|
25000
|
30000
|
|
Nominal AC output current [A]
|
12.2/11.6
|
15.2/14.5
|
18.2/17.4
|
22.8/21.8
|
25.8/24.7
|
30.3/29
|
37.9/36.3
|
45.5/43.5
|
|
Max. AC output apparent power [VA]
|
8800
|
11000
|
13200
|
16500
|
18700
|
22000
|
27500
|
30000
|
|
Max. AC output current [A]
|
13.2
|
16
|
19.3
|
24.2
|
27.5
|
33.6
|
41.8
|
45.5
|
|
Nominal AC voltage [V]
|
220/380, 230/400, 3/N/PE, 3/PE
|
|||||||
|
Nominal grid frequency [Hz]
|
50/60
|
|||||||
|
Displacement power factor
|
0.8 leading ~ 0.8 lagging
|
|||||||
|
THDi (Rated power) [%]
|
<3
|
|||||||
|
SYSTEM DATA
|
||||||||
|
Max. eciency [%]
|
98.20
|
98.30
|
98.50
|
|||||
|
Euro eciency [%]
|
97.70
|
97.80
|
98.00
|
|||||
|
Standby consumption(Night) [W]
|
<3
|
|||||||
|
Ingress protection
|
IP66
|
|||||||
|
Operating temperature range [°C]
|
-30~+60 (Derating above 45)
|
|||||||
|
Max. operation altitude [m]
|
4000 (Derating above 3000)
|
|||||||
|
Relative humidity [%]
|
0~100
|
|||||||
|
Typical noise emission [dB]
|
<35
|
<55
|
<58
|
|||||
|
Storage temperature [°C]
|
-30~+60
|
|||||||
|
Dimensions (W×H×D) [mm]
|
482×417×181
|
|||||||
|
Weight [kg]
|
24.5
|
26
|
28
|
|||||
|
Cooling concept
|
Natural cooling
|
Smart fan cooling
|
||||||
|
Communication interfaces
|
USB / RS485 / DRM / Pocket WiFi (Optional: Pocket LAN/4G) / Adapter box (Optional)
|
|||||||
|
PROTECTION
|
||||||||
|
Over/under voltage protection
|
YES
|
|||||||
|
DC isolation protection
|
YES
|
|||||||
|
Grid monitoring
|
YES
|
|||||||
|
DC injection monitoring
|
YES
|
|||||||
|
Residual current detection
|
YES
|
|||||||
|
Anti-islanding protection
|
YES
|
|||||||
|
Over Temp protection
|
YES
|
|||||||
|
SPD (DC/AC)
|
Type II / Type II
|
|||||||
|
AC auxiliary power supply (APS)
|
Optional
|
|||||||
|
Arc-fault circuit interrupter (AFCI)
|
Optional
|
|||||||
|
STANDARD
|
||||||||
|
Safety
|
IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004
|
|||||||
|
EMC
|
IEC/EN 61000; NB/T 32004
|
|||||||
|
Certification
|
VDE4105; EN 50549; AS 4777.2; VDE4105; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004
|
|||||||






