Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | Yes |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Smart Monitoring System
Technical specifications
X1-BOOST G3
|
||||||||
Model
|
X1-3.0/3.3/3.6/4.2/4.6/5/5.5/6-T-D(L)
X1-3.0/3.3/3.6/4.2/4.6/5/5.5/6-T-N(L)
|
|||||||
DC INPUT
|
||||||||
Max. PV array input power [Wp]
|
4500
|
4950
|
5400
|
6300
|
6900
|
7500
|
8250
|
9000
|
Max. DC input voltage [V]
|
600
|
|||||||
Startup voltage [V]
|
100
|
|||||||
Nominal input voltage [V]
|
360
|
|||||||
MPP tracker voltage range [V]
|
70 ~ 580
|
|||||||
No. of MPP trackers / Strings per MPP tracker
|
2/1
|
|||||||
Max. input current (Input A/Input B) [A]
|
14/14
|
|||||||
Max. short circuit current (Input A/Input B) [A]
|
16/16
|
|||||||
AC OUTPUT
|
||||||||
Nominal AC output power [W]
|
3000
|
3300
|
3680
|
4200
|
4600
|
5000
|
5500
|
6000
|
Nominal AC output current [A]
|
13
|
14.3
|
16
|
18.3
|
20
|
21.7
|
23.9
|
26.1
|
Max. output apparent power [VA]
|
3300
|
3630
|
4048
|
4620
|
5060
|
5500
|
6050
|
6600
|
Max. AC output current [A]
|
14.3
|
15.8
|
17.6
|
20.1
|
22
|
23.9
|
26.3
|
28.7
|
Nominal AC voltage [V]
|
220/230/240; 180~280
|
|||||||
Nominal grid frequency / Grid frequency range [Hz]
|
50/60; ±5
|
|||||||
Displacement power factor
|
0.8 leading ~ 0.8 lagging
|
|||||||
THDi (Rated power) [%]
|
<2
|
|||||||
SYSTEM DATA
|
||||||||
Max. Eciency [%]
|
97.80
|
|||||||
Euro. Eciency [%]
|
97.00
|
|||||||
Standby consumption [W] @Night
|
<2
|
|||||||
Degree of Protection
|
IP66
|
|||||||
Operating temperature range [°C]
|
-25~+60 (Derating at 45°C)
|
|||||||
Max. operation altitude [m]
|
≤3000
|
|||||||
Relative humidity [%]
|
0~100 (Condensing)
|
|||||||
Typical noise emission [dB]
|
30
|
|||||||
Storage temperature [°C]
|
-30~+70
|
|||||||
Dimensions (W × H × D) [mm]
|
341.5 × 430 × 143
|
|||||||
Net weight [kg]
|
13.5
|
15
|
||||||
Cooling concept
|
Natural Cooling
|
|||||||
Communication interfaces
|
Pocket WiFi / (Opitional: Pocket LAN/4G) / RS485 / DRM / USB / (Optional: CT/Meter)
|
|||||||
PROTECTION
|
||||||||
Over/under voltage protection
|
YES
|
|||||||
DC isolation protection
|
YES
|
|||||||
Monitoring ground fault protection
|
YES
|
|||||||
Grid monitoring
|
YES
|
|||||||
DC injection monitoring
|
YES
|
|||||||
Back feed current monitoring
|
YES
|
|||||||
Residual current detection
|
YES
|
|||||||
Anti-islanding protection
|
YES
|
|||||||
Over temperature protection
|
YES
|
|||||||
SPD
|
YES
|
|||||||
STANDARD
|
||||||||
Safety
|
EC/EN 62109-1/-2
|
|||||||
EMC
|
EN61000-6-1/2/3/4, EN61000-3-2/3/11/12
|
|||||||
Certification
|
IEC61727, EN50549, G98/G99, AS 4777.2, VDE4105, CEI 0-21, RD1699, UNE 206007-1, VFR
|