After-sales Service: | Yes |
---|---|
Warranty: | Yes |
Nature of Source Flow: | Passive inverter |
Phase: | Three |
Output Power: | >1000W |
Certification: | SAA, CE, ROHS, ISO9001 |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Smart Monitoring System
Technical specifications
Model
|
X3-FTH-80/100/110/120/125/136/150K
|
||||||
DC INPUT
|
|||||||
Max. PV array input power [kWp]
|
120
|
150
|
165
|
180
|
188
|
204
|
225
|
Max. PV input voltage [V]
|
1100
|
||||||
Startup voltage [V]
|
200
|
||||||
Nominal input voltage [V]
|
580/600
|
730/785
|
|||||
MPP tracker voltage range [V]
|
180~1000
|
||||||
No. of MPP trackers
|
9
|
12
|
|||||
Strings per MPP tracker
|
2
|
||||||
Max. input current per MPPT [A]
|
32
|
||||||
Max. short circuit current per MPPT [A]
|
46
|
||||||
AC OUTPUT
|
|||||||
Nominal AC output power [kW]
|
80
|
100
|
110
|
120
|
125
|
136
|
150
|
Nominal AC output current [A]
|
121.3
/116
|
151.6
/145
|
166.7
/159.5
|
181.9
/174
|
189.4
/181.2
|
157.1
/145.4
|
173.2/160.4
|
Max. AC output apparent power [kVA]
|
88
|
110
|
121
|
132
|
132
|
149.6
|
165
|
Max. AC output current [A]
|
133.4
/127.6
|
166.7
/159.5
|
183.4
/175.4
|
200
/191.3
|
200
/191.3
|
172.8
/160
|
190.6
/176.5
|
Nominal AC voltage[V]
|
220/380, 230/400, 3/N/PE, 3/PE
|
500/540,3P3W+PE
|
|||||
Nominal grid frequency [Hz]
|
50/60
|
||||||
Displacement power factor
|
0.8 leading-0.8 lagging
|
||||||
THDi (Rated power) [%]
|
<3
|
||||||
SYSTEM DATA
|
|||||||
MPPT efficiency [%]
|
99.9
|
||||||
Max. efficiency [%]
|
98.6
|
99.0
|
|||||
Ingress protection
|
IP66
|
||||||
Operating temperature range [ ºC]
|
-30~+60 (Derating above 45)
|
||||||
Max. operation altitude [m]
|
4000 (Derating above 3000)
|
||||||
Relative humidity [%]
|
0~100
|
||||||
Dimensions[W×H×D] [mm]
|
985×660×327.5
|
||||||
Weight [kg]
|
83
|
87
|
|||||
Cooling concept
|
Smart fan cooling
|
||||||
Communication interfaces
|
RS485 / (Optional: Pocket WiFi/LAN/4G) / PLC(Optional) / USB
|
||||||
Display
|
LCD(Optional)/LED*4
|
||||||
PROTECTION
|
|||||||
Over/under voltage protection
|
YES
|
||||||
DC isolation protection
|
YES
|
||||||
Grid monitoring
|
YES
|
||||||
DC injection monitoring
|
YES
|
||||||
Residual current detection
|
YES
|
||||||
Anti-islanding protection
|
YES
|
||||||
String fault detection
|
YES
|
||||||
SPD (DC/AC)
|
Type II / Type II
|
||||||
Arc-fault circuit interrupter(AFCI)
|
Optional
|
||||||
AC terminals over temperature detection
|
YES
|
||||||
AC auxiliary power supply(APS)
|
Optional
|
||||||
Power line communication(PLC)
|
Optional
|
||||||
STANDARD
|
|||||||
Safety
|
IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004
|
||||||
EMC
|
IEC/EN 61000; NB/T 32004
|
||||||
Certifification
|
EN 50549; AS4777.2; VDE4105; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004
|
Suppliers with verified business licenses