Technical specifications
X1-MINI G3
|
|||||||||
Model
|
X1-0.6/0.7/1.1/1.5/2.0/2.5/3.0/3.3/3.6-S-D(L)
X1-0.6/0.7/1.1/1.5/2.0/2.5/3.0/3.3/3.6-S-N(L)
|
||||||||
DC INPUT
|
|||||||||
Max. PV array input power [Wp]
|
900
|
1050
|
1650
|
2250
|
3000
|
3750
|
4500
|
4950
|
5400
|
Max. DC input voltage [V]
|
450
|
550
|
|||||||
Startup voltage [V]
|
50
|
70
|
|||||||
Nominal input voltage [V]
|
360
|
||||||||
MPP tracker voltage range [V]
|
45 ~ 430
|
50 ~ 430
|
55 ~ 530
|
||||||
No. of MPP trackers / Strings per MPP tracker
|
1/1
|
||||||||
Max. input current [A]
|
14
|
||||||||
Max. short circuit current [A]
|
16
|
||||||||
AC OUTPUT
|
|||||||||
Nominal AC output power [W]
|
600
|
700
|
1100
|
1500
|
2000
|
2500
|
3000
|
3300
|
3680
|
Nominal AC output current [A]
|
2.61
|
3.04
|
4.78
|
6.52
|
8.7
|
10.8
|
13.04
|
14.3
|
16
|
Max. output apparent power [VA]
|
660
|
770
|
1210
|
1650
|
2200
|
2750
|
3300
|
3300
|
3680
|
Max. AC output current [A]
|
2.9
|
3.3
|
5.3
|
7.2
|
9.6
|
11.9
|
14.3
|
14.3
|
16
|
Nominal AC voltage [V]
|
220/230/240;180 ~ 280
|
||||||||
Nominal grid frequency / Grid frequency range [Hz]
|
50/60;±5
|
||||||||
Displacement power factor
|
0.8 leading ~ 0.8 lagging
|
||||||||
THDi (Rated power) [%]
|
<3
|
||||||||
SYSTEM DATA
|
|||||||||
Max. Eciency [%]
|
98
|
||||||||
Euro. Eciency [%]
|
95.00
|
95.50
|
96.00
|
96.50
|
|||||
Standby consumption [W] @Night
|
0
|
||||||||
Degree of Protection
|
IP66
|
||||||||
Operating temperature range [°C]
|
-25 ~ +60 (derating at 45)
|
||||||||
Max. operation altitude [m]
|
≤2000
|
||||||||
Humidity [%]
|
0~100 (condensation)
|
||||||||
Typical noise emission [dB]
|
30
|
||||||||
Storage temperature [°C]
|
-30~+70
|
||||||||
Dimensions (WxHxD) [mm]
|
267 x 328 x 126
|
||||||||
Net weight [kg]
|
6
|
8.3
|
|||||||
Cooling concept
|
Natural cooling
|
||||||||
Communication interfaces
|
RS485 / DRM / Pocket WiFi / (Optional: Pocket LAN/4G) / USB/ (Optional: CT/Meter)
|
||||||||
PROTECTION
|
|||||||||
Over/under voltage protection
|
YES
|
||||||||
DC isolation protection
|
YES
|
||||||||
Monitoring ground fault protection
|
YES
|
||||||||
DC injection monitoring
|
YES
|
||||||||
Back feed current monitoring
|
YES
|
||||||||
Residual current detection
|
YES
|
||||||||
Anti-islanding protection
|
YES
|
||||||||
Over temperature protection
|
YES
|
||||||||
SPD
|
YES
|
||||||||
STANDARD
|
|||||||||
Safety
|
EN/IEC62109-1/-2
|
||||||||
EMC
|
EN61000-6-1/2/3/4;EN61000-3-2/3/11/12
|
||||||||
Certification
|
IEC61727, EN50549, G98/G99, AS 4777.2, VDE4105, CEI 0-21, RD1699, UNE 206007-1, VFR
|