Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | Yes |
Still deciding? Get samples of US$ 2556/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Smart Monitoring System
Technical specifications
Model
|
X3-MIC-3K-G2
|
X3-MIC-4K-G2
|
X3-MIC-5K-G2
|
X3-MIC-6K-G2
|
X3-MIC-8K-G2
|
X3-MIC-10K-G2
|
X3-MIC-12K-G2
|
X3-MIC-15K-G2
|
DC INPUT
|
||||||||
Max. PV array input power [Wp]
|
6000
|
8000
|
10000
|
12000
|
16000
|
20000
|
24000
|
30000
|
Max. PV input voltage [V]
|
1000
|
|||||||
Startup voltage [V]
|
150
|
|||||||
Nominal input voltage [V]
|
640
|
|||||||
MPP tracker voltage range [V]
|
120~980
|
|||||||
No. of MPP trackers/Strings per MPP tracker
|
2(1/1)
|
|||||||
Max. input current[A]
|
16/16
|
|||||||
Max. short circuit current[A]
|
20/20
|
|||||||
AC OUTPUT
|
||||||||
Nominal AC output power [W]
|
3000
|
4000
|
5000
|
6000
|
8000
|
10000
|
12000
|
15000
|
Nominal AC output current [A]
|
4.6/4.4
|
6.1/5.8
|
7.6/7.3
|
9.1/8.7
|
12.2/11.6
|
15.2/14.5
|
18.2/17.4
|
22.7/21.8
|
Max. AC output apparent power [VA]
|
3300
|
4400
|
5500
|
6600
|
8800
|
11000
|
13200
|
15000
|
Max. AC output current [A]
|
4.8
|
6.4
|
8.0
|
9.6
|
12.8
|
16.0
|
19.1
|
22.7
|
Nominal AC voltage [V]
|
220/380V, 230/400V, 3/N/PE
|
|||||||
Nominal grid frequency/Grid frequency [Hz]
|
50/60
|
|||||||
Displacement power factor
|
0.8 leading-0.8 lagging
|
|||||||
THDi (Rated power) [%]
|
<3
|
|||||||
SYSTEM DATA
|
||||||||
Max. efficiency [%]
|
98.3
|
|||||||
Euro efficiency [%]
|
97.8
|
|||||||
Standby consumption (night) [W]
|
<3
|
|||||||
Ingress protection
|
IP66
|
|||||||
Operating temperature range [ºC]
|
-30~+60(Derating above 45)
|
|||||||
Max. operation altitude [m]
|
4000(Derating above 3000)
|
|||||||
Relative humidity [%]
|
0~100
|
|||||||
Typical noise emission [dB]
|
<30
|
|||||||
Storage temperature [O C]
|
-30~+60
|
|||||||
Dimensions (W×H×D) [mm]
|
342*434*144.5
|
|||||||
Weight [kg]
|
15.5
|
17
|
18
|
|||||
Cooling concept
|
Natural cooling
|
Smart fan cooling
|
||||||
Communication interfaces
|
USB / RS485 / DRM / Pocket WiFi (Optional: Pocket LAN/4G) / Adapter box(Optional)
|
|||||||
PROTECTION
|
||||||||
Over/under voltage protection
|
YES
|
|||||||
DC isolation protection
|
YES
|
|||||||
DC reverse protection
|
YES
|
|||||||
Grid monitoring
|
YES
|
|||||||
DC injection monitoring
|
YES
|
|||||||
Back feed current monitoring
|
YES
|
|||||||
Residual current detection
|
YES
|
|||||||
Anti-islanding protection
|
YES
|
|||||||
Over temperature protection
|
YES
|
|||||||
SPD (DC/AC)
|
Type III / Type III
|
|||||||
Arc-fault circuit interrupter(AFCI)
|
Optional
|
|||||||
AC auxiliary power supply(APS)
|
Optional
|
|||||||
STANDARD
|
||||||||
Safety
|
IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004
|
|||||||
EMC
|
IEC/EN 61000; NB/T 32004
|
|||||||
Cetifification
|
VDE4105; EN 50549; AS 4777.2; VDE4105; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004
|