After-sales Service: | Yes |
---|---|
Warranty: | Yes |
Nature of Source Flow: | Passive inverter |
Phase: | Single |
Output Power: | >1000W |
Certification: | SAA, CE, ROHS, ISO9001 |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Smart Monitoring System
Technical specifications
Model
|
X1-HYBRID-3.0/3.7/4.6/5T
|
|||
INPUT (DC)
|
C-version E-v I-v
|
|||
Max.PV arroy power [Wp]
|
4500
|
5500
|
6900
|
7500
|
Max.recommended DC power[W]
|
A:3000
B:3000
|
A:3000
B:3000
|
A:3000
B:3000
|
A:3000
B:3000
|
MaX.DC voltage [V]
|
600
|
600
|
600
|
600
|
Nominal DC operating voltage [V]
|
360
|
|||
Max.input current (input A/input B) [A]
|
12/12
|
|||
Max. short circuit current (input A/input B) [A]
|
14/14
|
|||
MPPF voltage range [V]
|
125-550
|
|||
Start operating voltage[V]
|
150
|
|||
No. of MPP trackers / Strings per MPP tracker
|
2(1/1)
|
|||
INPUT AC
|
||||
Max. apparent AC power[VA]
|
3000 3000 7000
|
3680 3680 7680
|
4600 4600 9600
|
4999 4999 9999
|
Max. AC current [A]
|
14.4 14.4
30.4
|
16.0 16.0 33.4
|
21.0 21.0 41.7
|
21.7 21.7 42.7
|
Nominal grid voltage(AC voltage range)[V]
|
220/230/240(180-270)
|
|||
Norrinal grid Frequency/range [Hz]
|
50/60
|
|||
OUTPUT AC
|
||||
Nominal AC power [VA]
|
3000
|
3680
|
4600
|
4999
|
Max. apparent AC power [VA]
|
3300
|
4048(3680 for G98)
|
5060
|
5500 [4999 for AS47774600 for VDE4105)
|
Nominal grid voltage(AC voltage range) [V]
|
220/230/240(180-270)
|
|||
Norrinal grid Frequency/range [Hz]
|
50/60
|
|||
Nominal AC current [A]
|
13
|
16
|
20
|
21.7
|
Max. AC current [A]
|
14.4
|
16
|
21
|
23.9120 for VDE4105.21.7 for AS477)
|
Displacement power factor
|
0.8leading..0.8lagging
|
|||
THDi, rated power [%]
|
<2
|
|||
OUTPUT DC (BATTERY)
|
||||
Battery voltage range [V]
|
85-400
|
|||
Recommended battery voltage [V]
|
300
|
|||
Max.continuous charge/discharge current [A]
|
20
|
|||
Communication interfaces
|
CAN/RS485
|
|||
Reverse connect protection
|
Yes
|
|||
EPS OUTPUT (WITH BATTERY)
|
||||
EPS MAX. continuous apparent power [VA]
|
4000
|
4000
|
5000
|
5000
|
EPS rated voltage[V],Frequency [Hz]
|
230.50/60
|
|||
EPS MAX.continuous current [A]
|
21.7
|
21.7
|
26.0
|
26.0
|
EPS peak apparent power [VA] Duration [s]
|
8000 10
|
|||
Changeover time [ms]
|
<20 for l version / <500 for E version
|
|||
THDv, linear Load [%]
|
<2
|
|||
EFFICIENCY
|
||||
MPPT efficiency [%]
|
99.9
|
|||
Euro efficiency [%]
|
97.0
|
|||
Max. efficiency [%]
|
97.8
|
|||
Battery charge/discharge efficiency [%]
|
98.5 (PV-BAT) 97.0 (BAT-AC)
|
|||
POWER CONSUMPTION
|
||||
Standby consumption (Night) [W]
|
<15 for hot standby, <3 for cold standby
|
|||
STANDARD
|
||||
Safety
|
IEC62109-1/-2
|
|||
EMC
|
EN61000-6-1/EN61000-6-2/EN61000-6-3
|
|||
Certification
|
VDE 0126-1-1 A1:2012/VDE-AR-N 4105 /G99 /G98/AS4777/EN50549/ CE1 0-21 /VDE 2510 / and so on
|
|||
ENVIRONMENT LIMIT
|
||||
Degree of protection(according to IEC60529)
|
IP65
|
|||
Operating temperature range [ºC]
|
-20~+60 (derating at+45)
|
|||
Max.Operation atitude [m]
|
<2000
|
|||
Humidity [%]
|
0~100(non-condensing)
|
|||
Storage temperature [ºC]
|
-20~+60
|
|||
Typical noise emission [dB]
|
40
|
|||
DIMENSION AND WEIGHT
|
||||
Dimensions (W*H*D) [mm]
|
476*464*180
|
|||
Weight lkg]
|
24
|
|||
Cooling concept
|
Natural
|
|||
Topology
|
Non-isolated
|
|||
Communication interfaces
|
Ethernet/Meter/Pocket WiFi(optional)/Pocket LAN(optional)/Pocket GPRS(optional)/DRM/USB/ISO alarm/CT
|
|||
LCD display
|
Backlight 20*4 character
|
|||
Standard warranty [years]
|
5-10
|
Suppliers with verified business licenses